Note: The server IP must be public, without internal redirection (DST-NAT)
Note: It is necessary to enter the IP blocks, otherwise it will not be possible to grant access to Made4graph to the client's network
For the correct operation of Made4Graph, it is necessary to configure the PPPoE routers (NAS/BRAS) and also the ERP/Radius system, in addition to some parameters of the Made4Graph itself.
Below is the list of information and settings that we need:
Note:
The SNMP query must be released for the IP of the Made4Graph server.
For Huawei, Cisco, and Juniper routers, we use access via SSH/Telnet and also Netconf. To work, it is necessary to create a read-only user for us, allowing access from the IP of the Made4Graph server. The Netconf (830/TCP) and also SSH (22/TCP) ports must be released.
If the “Manufacturer” Vendor is **HUAWEI, ** it is necessary to release the NETCONF query for made4graph, according to the wiki below:
However, if the NAS version is lower than what is described on the wiki, it is necessary to grant SSH query access to the made4graph user on the NAS
For the disconnect and release the band buttons to work, it will be necessary to enable radius incomming on your device, which will be registered with Made4Graph.
Command examples are below. Adapt them according to your router.
To find out the commands for your router model, go to:
We use the data from your system's RADIUS server or API to find the connected users, and also the information from which router each client connects.
For such access to this database, we need the following information:
If your bank is consulted via API, we need the following information:
**Remarks: **
ACCESS TO CPEs FOR APPROVAL
To approve the first three CPEs on made4graph via TR-069, we need some access information
Access data for the First CPE:
Access data for the Second CPE:
Access data to the Third CPE:
Note: The routers we have approved today are:
If the CPE model you have at your ISP is not on the list, don't worry, I'll put it on a bench, which we will approve, if problems occur during approval, or if the CPE does not provide all the necessary information, a report will be made to you the customer, so that we can together adjust the problems related to the CPE
Note: For the first approval, the CPE IPs must be public, otherwise it will make approval difficult or even impossible
Note: The CPE must be countertop, as we carry out several tests on it, which may impair the clients' connection, if done directly from the customer's home